Default Re: Hydraulic Q's

As you retract the cylinder the rod takes up space and not as much fluid is needed to move the piston as what is needed to extend the cylinder. The level of the fluid in the tank will go up and down with these actions. You should have some air space in the tank when the excavator is in the ready position (boom up with the stick strait up and down). In this position the cylinders should be close to half stroke. As RCP57 said the breather should be open so the tank doesn't build up pressure or vacuum (what it does) which will cause the pump to labor or the tank to collapse or explode if it is not open (the purpose).


Travis
__________________
AKA "00" Biddle


RIP FreddyGearDrive 2-12-59/12-19-11
Reply With Quote
 


Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 09:39 PM.


Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.