RC Truck and Construction  

Go Back   RC Truck and Construction > RC Truck's Ag and Industrial Equipment and Buildings > Construction Equipment > Construction Equipment Tech

Construction Equipment Tech Hydraulics, Electronics, General Engineering, ect in constr equip


Reply
 
Thread Tools Display Modes
  #1  
Old 03-15-2012, 05:21 PM
carp carp is offline
Green Horn
 
Join Date: Oct 2010
Location: USA
Posts: 164
carp is on a distinguished road
Default Re: Direct drive pump

there is a thread somewhere that shows a motor coupled via direct drive i will try to find it, that 5065 motor is quite a lump what sort of runtime would you get with that? im assuming that it isnt running flat out
Reply With Quote
  #2  
Old 03-16-2012, 02:37 AM
Vanisle Vanisle is offline
Green Horn
 
Join Date: Oct 2010
Location: Vancouver Island
Posts: 156
Vanisle is on a distinguished road
Default Re: Direct drive pump

No idea about runtime with a 5065 (which is significantly larger than a 4250). I don't have one and just remember seeing someone on a German forum mention it versus a smaller motor with a 3:1 planetary. I see that RCP57 did up a driect drive (on his excavator thread) so it looks like he got it figured out.
Reply With Quote
Reply


Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 02:12 AM.


Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.